Back to all papers

Low-dose CT denoising using a diffusion prior via score distillation sampling.

October 26, 2026pubmed logopapers

Authors

Jung H,Lee J,Baek J

Affiliations (2)

  • Department of Artificial Intelligence, Yonsei University, Seoul, Republic of Korea.
  • Bareunex Imaging, Inc., Seoul, Republic of Korea.

Abstract

Low-dose computed tomography (LDCT) reduces radiation exposure but amplifies noise, which can degrade diagnostic reliability. Recent studies have applied diffusion-based models to LDCT denoising and shown promising performance. However, many of these approaches require paired LDCT and normal-dose CT (NDCT) data or dose-specific retraining, and their reconstruction procedures are often strictly coupled to a predefined diffusion trajectory. This study proposes an optimization-based LDCT denoising framework that uses a pre-trained NDCT diffusion model as an image prior and can be applied across various dose levels without dose-specific retraining. We formulate LDCT denoising as an optimization problem guided by a pre-trained score-based generative model (SGM) trained only on NDCT images. The Poisson data fidelity term enforces consistency with the measured projection data, whereas the score distillation sampling (SDS) term acts as a regularizer that guides the reconstruction toward the NDCT distribution learned by the pre-trained SGM. The denoised image is obtained by iteratively optimizing a projection-domain residual variable using the combined Poisson data fidelity gradient and SDS-based regularization gradient. The proposed method effectively suppressed noise while preserving fine anatomical structures across multiple dose levels using a single pre-trained diffusion model. Quantitative evaluations with respect to full-dose reference images and visual comparisons demonstrated competitive performance compared with supervised and self-supervised LDCT denoising baselines. The results show that diffusion-based image priors can be leveraged across various low-dose levels within the proposed optimization-based denoising framework. Our work suggests that SDS-guided diffusion priors are a promising direction for LDCT denoising in data-limited settings.

Topics

Tomography, X-Ray ComputedRadiation DosageSignal-To-Noise RatioImage Processing, Computer-AssistedJournal Article

Ready to Sharpen Your Edge?

Subscribe to join 11k+ peers who rely on RadAISlice. Get the essential weekly briefing that empowers you to navigate the future of radiology.

We respect your privacy. Unsubscribe at any time.