Sex-based differences in proximal femoral landmark distances relative to femoral head centre: An artificial intelligence-assisted three-dimensional computed tomography study.
Authors
Affiliations (9)
Affiliations (9)
- Department of Anatomy, Faculty of Medicine, School of Health Sciences University of Thessaly Larissa Greece.
- Department of Clinical Research, Regenerative Medicine and Biomechanics University of Basel Basel Switzerland.
- Royal College of Surgeons Ireland Dublin Ireland.
- Pasteur II Hospital University Institute of Locomotor and Sports (iULS) Nice France.
- ICARE Unit, Inserm U1091 Côte d'Azur University Nice France.
- Akmelogi SMPC Athens Greece.
- 3 PSI Ltd Larnaka Cyprus.
- Department of Orthopaedic Surgery and Musculoskeletal Trauma, University Hospital of Larissa, Faculty of Medicine, School of Health Sciences University of Thessaly Larissa Greece.
- Orthopaedics and Traumatology Department Central Military University Emergency Hospital 'Carol Davila' Bucharest Romania.
Abstract
To assess sex-based differences in three-dimensional (3D) distances from the greater trochanter (GT), digital fossa (DF) and lesser trochanter (LT) to the femoral head centre (FHC) in native femora and determine whether these differences persist after normalization to femoral length. A retrospective cross-sectional study was performed using post-mortem computed tomography data on 195 adults aged 45-75 years with no radiological signs of osteoarthritis and no prior hip surgery. One femur per subject was randomly selected from bilateral cases. 3D Euclidean distances (ED) from the GT, DF and LT to the FHC were determined. Femoral offset, anteversion and neck-shaft angle (NSA) were recorded as secondary outcomes. A custom-made artificial intelligence planning software was used for landmark detection and for extracting all of the above-mentioned parameters. Femoral anteversion was greater in females (16.03° vs. 10.60°; <i>p</i> < 0.001), and femoral offset was greater in males (34.95 vs. 32.20 mm; <i>p</i> = 0.004). After adjustment for femoral length, GT-FHC, DF-FHC, LT-FHC and GT-LT distances remained greater in males, with adjusted differences of 2.89 mm (95% confidence interval [CI] 1.33-4.45), 3.11 mm (1.89-4.33), 3.11 mm (1.67-4.54) and 3.85 mm (2.31-5.39), respectively (all false discovery rate [FDR]-adjusted <i>p</i> < 0.001). Anteversion decreased and offset increased with length (FDR-adjusted <i>p</i> = 0.028 and 0.038), without significant adjusted sex differences. The GT-FHC, DF-FHC, LT-FHC and LT-GT distances are influenced by sex and femoral length and remained greater in males after adjustment. Anteversion and offset were associated with length without significant adjusted sex differences; NSA demonstrated neither association. Sex influenced in a larger percentage only the DF-FHC distance in exploratory analysis. The clinical reliability of these landmarks and their implementation in templating for total hip arthroplasty and accurate FHC restoration require further investigation. Level III.