Back to all papers

Validation of an Automated Artificial Intelligence-Driven Planner for Transcatheter Aortic Valve Replacement.

August 5, 2026pubmed logopapers

Authors

van den Dorpel MMP,Uchoa de Assis L,van Niekerk J,Deckx S,Sherman M,Schrot J,Kozak A,Kardys I,Hirsch A,Daemen J,Nuis RJ,Van Mieghem NM

Affiliations (3)

  • Department of Cardiology, Cardiovascular Institute, Thoraxcenter, Erasmus Medical Center, Rotterdam, the Netherlands.
  • Materialise, Leuven, Belgium.
  • Department of Radiology and Nuclear Medicine, Erasmus Medical Center, Rotterdam, the Netherlands.

Abstract

Preprocedural planning with multislice computed tomography (MSCT) is an essential prerequisite for successful transcatheter aortic valve replacement (TAVR). However, preprocedural planning is time-consuming and may contain clinically meaningful interobserver variability. Artificial intelligence (AI) based automated planning methods may provide anatomical MSCT measurements while reducing the time load required for the analysis. Previous studies on the validation of AI-based TAVR planning methods excluded anatomical variants or lacked data on actual TAVR prosthesis size agreement. Mimics for TAVR (Materialise, Leuven, Belgium) is a new, AI-driven TAVR planning platform based on patient-specific 3D anatomical models and automated measurements through a web-based user interface. To validate the Mimics for TAVR planning tool in clinical practice. Key planning assessments were performed on pre-TAVR MSCT datasets using Mimics for TAVR and a commercially available semi-automated software package. Agreement between the two planning methods was assessed using intraclass correlation coefficients and Bland-Altman plots. A total of 126 consecutive patients (mean age 80 [74-85]; 56% male) who underwent MSCT as part of their TAVR work-up were included. Mimics for TAVR derived measurements showcased high accuracy and excellent agreement for the area of the aortic annulus (mean error ± SD: -1.9 ± 3.3%, ICC: 0.976 [95% CI: 0.966-0.984]), left ventricular outflow (-2.7 ± 3.8%, ICC: 0.970 [0.957-0.983]), sinotubular junction (-2.6 ± 4.2%, ICC: 0.953 [0.921-0.971]), coronary heights (LCA -3.5 ± 4.8%, ICC: 0.900 (0.859-0.928). RCA -3.9 ± 4.7%, ICC: 0.928 [0.898-0.949]) and membranous septum length (-5.0 ± 9.2%, ICC: 0.919 [0.880-0.940]). Mimics for TAVR assessment significantly reduced the time required for pre-TAVR analysis (1.03 ± 0.15 min vs. 9.55 ± 3.16 min per case, respectively (p = 0.001). The automated AI-driven Mimics for TAVR planner is an accurate alternative to existing semiautomated TAVR planning platforms and may enhance overall workflow efficiency.

Topics

Journal Article

Ready to Sharpen Your Edge?

Subscribe to join 11k+ peers who rely on RadAI Slice. Get the essential weekly briefing that empowers you to navigate the future of radiology.

We respect your privacy. Unsubscribe at any time.