Artificial Intelligence-Enabled Acquisition and Interpretation for Screening Aortic Stenosis.

August 28, 2026pubmed logopapers

Authors

Lee E,Naser JA,Kane CJ,Kovac JL,Greason C,Killalea MM,Gulati MA,Jackson JI,Borgeson J,Schonfeld DA,Malins JG,Anisuzzaman DM,Crestanello MM,Zacher J,Camalan S,Thaden JJ,Anand V,Nkomo VT,Padang R,Poterucha TJ,Chao CJ,Pellikka PA,Lopez-Jimenez F,Friedman PA,Oh JK,Kane GC,Attia ZI,Pislaru SV,Bird JG,Tsaban G

Affiliations (1)

  • Department of Cardiovascular Medicine, Mayo Clinic, Rochester, Minnesota.

Abstract

Timely identification of aortic stenosis (AS) is essential for appropriate clinical management, yet screening remains limited by dependence on comprehensive echocardiography and trained imaging personnel. To develop and validate a deep learning algorithm for detection of moderate or greater AS and prospectively evaluate its performance using artificial intelligence (AI)-guided focused cardiac ultrasound (FoCUS) acquired by novice operators. This diagnostic study included retrospective algorithm development and validation and prospective evaluation of AI-guided FoCUS across Mayo Clinic sites in the Midwest, Arizona, and Florida. The model was developed using 6753 patients and evaluated in internal validation (n = 852), internal test (n = 844), and validation (n = 1912) cohorts. Performance was assessed on FoCUS acquired by experienced sonographers (n = 602) and prospectively by novice operators (n = 1302). The retrospective model development and validation cohorts comprised studies performed from January 2005 through September 2022. Prospective study was conducted in 2 enrollment periods from June to August 2024 and from June to September 2025. Participants from both periods were combined to comprise the final prospective cohort. AI-guided FoCUS acquisition and automated deep learning-based assessment for detection of moderate or greater AS. Detection of moderate or greater AS. Performance was assessed using area under the receiver operating characteristic curve (AUROC), sensitivity, specificity, and positive predictive value. The model demonstrated excellent discrimination in the internal test cohort (AUROC, 0.99; 95% CI, 0.98-1.00) and geographically distinct validation cohorts in Arizona (AUROC, 0.99; 95% CI, 0.97-1.00) and Florida (AUROC, 0.99; 95% CI, 0.96-1.00). Among FoCUS examinations acquired by experienced sonographers, sensitivity was 95% (95% CI, 82-99) and specificity was 97% (95% CI, 95-98). In the prospective novice-operator cohort, 1258 of 1302 examinations (96.6%) were suitable for automated analysis. Sensitivity was 93% (95% CI, 82-99) and specificity was 96% (95% CI, 95-97). Expert review of AI-positive and uninterpretable examinations increased the positive predictive value from 49.4% to 91.1%, with sensitivity of 85.4%. A deep learning algorithm accurately detected moderate or greater AS across validation cohorts in this study. In prospective evaluation, novice operators were able to acquire AI-guided FoCUS examinations that enabled accurate detection of moderate or greater AS. These findings support a scalable strategy that may expand access to AS detection in settings with limited echocardiography resources.

Topics

Journal Article

Ready to Sharpen Your Edge?

Subscribe to join 11k+ peers who rely on RadAI Slice. Get the essential weekly briefing that empowers you to navigate the future of radiology.

We respect your privacy. Unsubscribe at any time.