Physics-Based Differentiable Beamforming for Deep Learning-Based Contrast Enhanced Ultrasound Super-Resolution Imaging
Authors
Abstract
Ultrasound is widely used for vascular imaging because it is non-invasive, real-time, and cost-effective. However, its spatial resolution remains limited by diffraction to an order of the acoustic wavelength. This limitation is particularly restrictive for imaging of the microvasculature and high-resolution vector-flow-imaging. In this work, we present a multi-channel physics-based deep learning approach to super-resolve monodisperse microbubbles directly from multi-channel radio-frequency (RF) data. We also present a novel image-based metric for model evaluation. The proposed pipeline combines a learnable deconvolution network with a differentiable beamforming layer, enabling a direct deconvolution of the microbubble (MB) signature prior to image formation. By operating on multi-channel RF data, the method aims to improve localization robustness in the presence of dense microbubble populations and deconvolve the lateral direction in a relatively low-frequency regime (1.7 MHz) where MBs exhibit nonlinear behavior. The model is trained and evaluated on simulated data using monodisperse lipid-coated MBs over a broad range of acoustic pressures and microbubble densities. The proposed method improves the signal-to-noise ratio (SNR) compared to the single-channel approach. It achieves sub-wavelength axial and lateral resolution while slightly improving robustness to dense microbubble populations outside the training domain. It also demonstrates generalizability across transmit configurations without requiring explicit training on each transmit configuration.