Back to all papers

Cardiac segmentation for ventricular tachycardia radioablation and radiotherapy patients with cardiac implants

September 28, 2026arxiv logopreprint

Authors

Nicholas Summerfield,Dustin Jacqmin,Chase Ruff,Andrew M. Baschnagel,Adam Burr,Michael Bassetti,Ryan Kipp,Matthew Kalscheur,Patrick M. Hill,Ming Dong,Carri Glide-Hurst

Abstract

Deep-learning (DL) segmentation enables cardiac substructure (CS) delineation for advanced cardiac-sparing radiation therapy (RT). Patients presenting for RT may have implantable devices (cardioverter-defibrillators (ICDs)) and metal artifacts. Stereotactic body RT (SBRT) is used to treat ventricular tachycardia (VT), a population frequently with ICDs. We apply a DL model for RT patients with ICDs or undergoing VT-SBRT, enabling segmentation and CS-level dose analysis. CT simulation (CT-SIM) of 19 patients with ICDs and received VT-SBRT were evaluated. A validated segmentation model was retrained using a highly-curated CT-SIM cohort, supplemented with ICD images for training and validation, with a hold-out ICD test set (n=10), to predict 20 CS. Additional CT-SIM datasets included cancer-RT patients with (n=9) and without (n=10) ICDs to evaluate generalizability. The retrained ICD-supplemented model was compared against a non-ICD model using Dice similarity coefficient (DSC), 95% Hausdorff distance (HD95), and Wilcoxon signed-rank test (p<0.05). Dosimetric evaluation was performed for VT-SBRT CS. For VT-SBRT, the ICD-supplemented model achieved average DSC/HD95 of 0.71(0.19)/10.7(22.5)mm respectively, outperforming (p<0.05) the non-ICD model. On CT-SIM with ICDs, average DSC/HD95 were 0.70(0.22)/7.9(5.1)mm respectively, outperforming (p<0.05) the non-ICD model. On CT-SIM without ICDs, the average DSC was 0.74(0.17) (Non-ICD, DSC, 0.75(0.16), p<0.05) and average HD95 was 5.5(3.1)mm (Non-ICD, HD95, 5.3(2.8mm)). For VT-SBRT, CS dose depended on target location, with higher relative dose delivered to the ventricles, tricuspid valve, atrioventricular node, and left coronary arteries than other CS. ICD-supplemented training improved CS segmentation despite metal artifacts without meaningfully degrading non-ICD performance, supporting segmentation and CS-level dosimetry in ICD populations.

Topics

physics.med-ph

Ready to Sharpen Your Edge?

Subscribe to join 11k+ peers who rely on RadAISlice. Get the essential weekly briefing that empowers you to navigate the future of radiology.

We respect your privacy. Unsubscribe at any time.